The Masimo Compatible Disposable SpO2 Sensor �Adult (�0kg) delivers reliable oxygen saturation monitoring with soft adhesive textile construction, designed for comfortable single-use application in adult clinical settings. Compatible with a wide range of monitors including Masimo Rad-5, Rad-8, Rad-97, Radical-7, Pronto-7; Mindray Datascope BeneView T1/T5/T8, DPM4/6/7, Passport 2/V/XG, Spectrum, V12/V21/VS 800; GE Healthcare Marquette Dash 2000/3000/4000/5000, Solar 7000/8000, TRAM Modular; GE Critikon Dinamap Carescape B650/B850/V100, ProCare 300/400; Philips; Stryker Physio Control Lifepak 11/12/15/20/20E; Zoll E/M/R/X Series; Welch Allyn Propaq CS/LT, Spot Vital Signs; Draeger Infinity M540, Narkomed 6400; Datex Ohmeda Giraffe Infant Warmer, S/5; Bitmos sat 800/801/805/816/satPuls; Respironics Alice 5; Mennen Horizon XVu; Invivo Escort II, OPT30, Prism, T3; and all Penlon InterMed models. Replaces OEM part numbers including GE Healthcare Marquette #2027253-001, Masimo #1859/#2317, Mindray #0600-00-0121/#520A-30-64101, Philips #989803148231, Physio Control #11171-000019, and Zoll #8000-0320. Sold in a box of 24, manufactured to CE and FDA standards with full regulatory traceability. Trusted by hospitals and clinical teams across the US for dependable SpO2 monitoring at up to 65% savings compared to OEM pricing. Ships from our California warehouse within 24�8 hours.
|
OEM Part Number Cross References: |
|
|
Manufacturer |
OEM Part # |
|
GE Healthcare > Marquette |
2027253-001 |
|
Masimo |
1859 LNCS Adtx (18"), 2317 (LNCS Adtx-3) (3 ft) |
|
Mindray > Datascope |
0600-00-0121, 520A-30-64101 |
|
Philips |
989803148231 |
|
Stryker > Medtronic > Physio Control |
11171-000019 |
|
Zoll |
8000-0320 |
|
Compatibility: |
|
|
Manufacturer |
Model |
|
Bitmos |
sat 800; sat 801; sat 805; sat 816; satPuls |
|
Datex Ohmeda |
Giraffe Infant Warmer; S/5 |
|
Draeger |
Infinity M540; Narkomed 6400 |
|
GE Healthcare > Corometrics |
128; 250; 250cx; TRAM 450SL |
|
GE Healthcare > Critikon > Dinamap |
Carescape B650; Carescape B850; Carescape V100; Carescape V100 with Masimo technology; Dinamap ProCare with Masimo Pro 1000; Pro 300V2; ProCare 300; ProCare Ausculatory 400; ProSeries V2; V300 |
|
GE Healthcare > Marquette |
8000 e Eagle 1000; Dash 2000; Dash 2500; Dash 3000; Dash 4000; Dash 5000; Dash Series; Eagle; PDM Module; Procare B40; SOLAR; Smk SMV; Solar 7000; Solar 8000; Solar 8000M; Solar Series; TRAM Modular; Tram 451; i/9500; i/9500 (Tram 451N5/851N5); x50SL Series |
|
Invivo |
Escort II OPT30 Prism; T8 |
|
Masimo |
All; Pronto-7; Rad-5; Rad-57; Rad-8; Rad-87; Radical-7 |
|
Mennen |
Horizon XVu |
|
Mindray > Datascope |
Accutor V; Accutorr 3; Accutorr 7; Accutorr Plus; Accutorr V; BeneView T1; BeneView T5; BeneView T8; Beneheart D6; DPM4; DPM6; DPM7; Duo; EPM4; MEC 12; MPM; PM 6000; PM 6800; PM 7000; PM 8000; PM 9000; Passport 12; Passport 2; Passport 2LT; Passport 8; Passport V; Passport XG; Spectrum; Spectrum OR; Trio; V12; V21; VS 800 |
|
Penlon InterMed |
All |
|
Respironics |
Alice 5 |
|
Stryker > Medtronic > Physio Control |
Lifepak 11; Lifepak 12; Lifepak 15; Lifepak 20; Lifepak 20E |
|
Welch Allyn |
1500; 45NE0-E1 LX; Propaq CS; Propaq LT; Spot Vital Signs 42MTB-E1; Spot Vital Signs lXi |
|
Zoll |
E Series; M Series; R Series; X Series |
|
Technical Specifications: |
|
|
Category |
Disposable SpO2 Sensors |
|
Regulatory compliance |
CE, FDA, Anvisa, MDSAP, ISO 80601-2-61, ISO 10993 series |
|
Monitor End Connector |
DB-9 Male, trislot |
|
Sensor Tech. |
Masimo |
|
Patient Size |
Adult(>30kg) |
|
Total Cable Length |
3ft |
|
Cable Color |
Gray |
|
Cable Diameter |
3.2mm |
|
Cable Material |
PVC Jacket |
|
Sensor Material |
Adhesive Textile |
|
Latex-free |
Yes |
|
Packaging Type |
box |
|
Packaging Unit |
24pcs |
|
Package Weight |