Nellcor-OXIMAX Compatible Disposable SpO2 Sensor Stretch Fabric - MAX-A

Part Number: PT503-01XP

SKU:

$233

Use this with:

The Nellcor OxiMax Compatible Disposable SpO2 Sensor Adult 40kg and above provides precise oxygen saturation monitoring using stretch fabric for adult patients. Replacing OEM parts Covidien Nellcor MAX-A, Draeger MX50065, GE Healthcare Marquette 70124027, and Stryker Medtronic Physio Control 11996-000113, this single-use sensor is compatible with an extensive range of patient monitors including GE Marquette Dash 2500, 3000, 4000, 5000, Solar 8000, Solar 8000M, Tram 451, V9500, Critikon Dinamap Carescape B650, Carescape V100, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, ProCare 200, ProCare 400, ProCare Ausculatory 400, Mindray Datascope Accutorr Plus, BeneView T1, DPM5, DPM6, DPM7, Duo, Expert, Passport series, Spectrum, Spectrum OR, Trio, V-Series, Medtronic Physio Control Lifepak 12 and 15, Draeger Narkomed 6400, BCI, Biolight M9500, Biosys BPM-200, Baxter Explorer and Monarch, CAS Med 511, Criticare, Digicare LW600, DRE, Fukuda Denshi, Goldway, and Midmark Cardell systems. CE, FDA certified with full regulatory traceability. Ships from our California warehouse within 24–48 hours at up to 65% savings compared to OEM pricing.

OEM Part Number Cross References:

Manufacturer

OEM Part #

Covidien > Nellcor

MAX-A

Draeger

MX50065

GE Healthcare > Marquette

70124027

Stryker > Medtronic > Physio Control

11996-000113

Compatibility:

Manufacturer

Model

Baxter

Explorer; Monarch

BCI

3100; 3101; 3180; 3300; 3301; 3302; 3303; 3304; 3401; 6100; 9100; Advisor; Autocorr; Mini Torr; Mini Torr Plus

Biolight

M9500

Biosys

BPM-200; SENTRY

CAS Med

CAS 511; 511

Criticare

506DNV3; 506DNVP3; 506LNV3; 506LNVP3; 506NV3; 506NVP3

Critikon/Dinamap

Carescape B650; Carescape V100; Compact Dinamap MPS; E-NSAT; Pro1000; Pro1000 V3; Pro200; Pro300; Pro Series V2; ProCare 200; ProCare 400; ProCare Ausculatory 400

Digicare

LW600

Draeger

Narkomed 6400

DRE

ASM 5000; Waveline; Waveline Plus

Fukuda Denshi

Dynascope DS-7100; LX-7230N

GE > Marquette

Dash 2500; Dash 3000; Dash 4000; Dash 5000 with Nellcor Oximax; Procare B40; Solar 8000; Solar 8000M; Tram 451; i/9500

GE Healthcare > Critikon > Dinamap

Carescape B650; Carescape V100; Compact DINAMAP MPS; E-NSAT; Pro 1000; Pro 1000 V3; Pro 200; Pro 300; Pro Series V2; ProCare 200; ProCare 400; ProCare Ausculatory 400

GE Healthcare > Marquette

Dash 2500; Dash 3000; Dash 4000; Dash 5000; PDM Module; Procare B40; Solar 8000; Solar 8000M; Tram 451; i/9500

Goldway

Vet 420A; Vet 600A

Medtronic > Physio Control

Lifepak 12; Lifepak 15

Midmark > Cardell

9403; 9405; 9500HD; 9500 Series; MAX-12 Duo HD

Mindray > Datascope

Accutorr Plus; BeneView T1; DPM5; DPM6; DPM7; Duo; Expert; Passport; Passport 12; Passport 2; Passport 8; Passport V; Passport XG; Spectrum; Spectrum OR; Trio; V-Series

Mindray

Accutorr Plus; DPM5; DPM6; DPM7; Duo; Expert; Passport; Passport 12; Passport 2; Passport 8; Passport V; Passport XG; Spectrum; Spectrum OR; Trio

Nellcor

N-10; N-180; N-190; N-20; N-30; N-560; N-600; N-600x; N-65; N-85; NPB-190; NPB-195; NPB-3910; NPB-3920; NPB-3930; NPB-3940; NPB-40; NPB-4000; NPB-75; PM10N; Sensors that have Nellcor OxiMax Technology and 9 pins

Omron > Colin

BP-S510; T105NXM

Philips

Heartstream XL; IntelliVue; IntelliVue FAST-SpO2; IntelliVue MP70; IntelliVue MX450; M1020B; M2601A; M3000A; M3001A MMS; M3001A; M3002A; M3002A MMS X2; M3500B; M4735A; M8102A; M8102A MP2; M8105A MP5; M8105 AS; SureSigns VS2; SureSigns VS3; IntelliVue MP2; M3001A A02; M3001A A02C06; M3001A A02C12; M3001A A02C18; M3001A A04; M3001A A04C06; M3001A A04C12; M3001A A04C18; M8105A MP5; M8105AS

Stryker > Medtronic > Physio Control

Lifepak 12; Lifepak 15

Welch Allyn

1500; 42NT0-E1 Lxi; 53NT0; 53NTP; Atlas (Nellcor SpO2); Atlas 6200 Series; Encore 202EL; Propaq 244; Propaq CS; Propaq LT; Spot Vital Signs 42NTB-E1; 42NT0-E1 LXi; All

Technical Specifications:

Category

Disposable SpO2 Sensors

Regulatory compliance

CE, FDA, Anvisa, MDSAP, ISO 80601-2-61, ISO 10993 series

Monitor End Connector

DB-9 Male, double-groove

Sensor Tech.

Nellcor-Oximax

Patient Size

Adult(>30kg)

Total Cable Length

3ft

Cable Color

Gray

Cable Diameter

3.2mm

Cable Material

PVC Jacket

Sensor Material

Stretch Fabric

Latex-free

Yes

Packaging Type

box

Packaging Unit

24pcs

Package Weight